  Datasheet File OCR Text:
 Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type: Date:
B41888 November 2008
(c) EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Single-ended capacitors Extended useful life 105 C
B41888
Long-life grade capacitors Very low impedance Applications Automotive electronics For use in switch-mode power supplies For professional industrial electronics, telecommunications and data processing equipment Features Long useful life Very low impedance at high frequency High ripple current capability RoHS-compatible Construction Radial leads Charge-discharge proof, polar Aluminum case with insulating sleeve Minus pole marking on the insulating sleeve Case with safety vent Delivery mode Terminal configurations and packing: Bulk Taped, Ammo pack Cut Kinked PAPR (protection against polarity reversal): crimped leads, J leads, bent leads Refer to chapter "Single-ended capacitors Taping, packing and lead configurations" for further details and ordering example.
Please read Cautions and warnings and Important notes at the end of this document.
Page 2 of 32
B41888 Extended useful life 105 C
Specifications and characteristics in brief Rated voltage VR Surge voltage VS Rated capacitance CR Capacitance tolerance Dissipation factor tan (20 C, 120 Hz) 10 ... 63 V DC 1.15 VR 56 ... 10000 F 20% M For capacitance higher than 1000 F add 0.02 for every increase of 1000 F. VR (V DC) tan (max.) Leakage current Ileak (20 C, 5 min) Self-inductance ESL Useful life 105 C; VR; IAC,R 10 0.18 16 0.16 25 0.14 35 0.12 50 0.10 63 0.09
Diameter (mm) ESL (nH)
12.5 20
16 26
18 34
> 5000 h for d = 8 mm > 7000 h for d = 10 mm > 10000 h for d 12.5 mm C/C tan Ileak 40% of initial value 3 times initial specified limit initial specified limit
Requirements
Voltage endurance test 105 C; VR
5000 h for d = 8 mm 7000 h for d = 10 mm 10000 h for d 12.5 mm C/C tan Ileak 30% of initial value 2 times initial specified limit initial specified limit
Post test requirements
Vibration resistance test
To IEC 60068-2-6, test Fc: Displacement amplitude 1.5 mm, frequency range 10 ... 2000 Hz, acceleration max. 20 g, duration 3 x 2 h. Capacitor rigidly clamped by the aluminum case. To IEC 60068-1: 55/105/56 ( 55 C/+105 C/56 days damp heat test) AEC-Q200, IEC 60384-4
IEC climatic category Sectional specification
Please read Cautions and warnings and Important notes at the end of this document.
Page 3 of 32
B41888 Extended useful life 105 C
Dimensional drawings With stand-off rubber seal Diameters (mm): 10, 12.5, 16, 18 With flat rubber seal Diameter (mm): 8
Dimensions and weights Dimensions (mm) d +0.5 8 10 10 10 12.5 12.5 12.5 16 16 16 18 18 18 18 18 Approx. weight g 1.0 1.6 1.9 2.6 3.6 4.5 7.4 5.5 7.5 7.8 8.0 9.0 11.0 13.0 16.0
l 11.5 +1.5 12.5 +1.0 16 +1.0 20 +2.0 20 +2.0 25 +2.0 40 +2.0 20 +2.0 25 +2.0 31.5 +2.0 20 +2.0 25 +2.0 31.5 +2.0 35 +2.0 40 +2.0
a 0.5 3.5 5.0 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
b 0.60 0.05 0.60 0.05 0.60 0.05 0.60 0.05 0.60 0.05 0.60 0.05 0.80 0.05 0.80 0.05 0.80 0.05 0.80 0.05 0.80 0.1 0.80 0.1 0.80 0.1 0.80 0.1 0.80 0.1
Please read Cautions and warnings and Important notes at the end of this document.
Page 4 of 32
B41888 Extended useful life 105 C
Overview of available types VR (V DC) CR (F) 56 68 82 100 120 150 180 220 270 330 390 470 560 680 8 10 10 x 11.5 x 12.5 x 12.5 8 8 10 10 10 x 11.5 x 11.5 x 12.5 x 16 x 16 8 8 10 10 10 10 10 x 11.5 x 11.5 x 12.5 x 12.5 x 16 x 16 x 20 10 10 10 x 20 x 20 x 20 12.5 x 20 12.5 x 25 12.5 x 25 8 10 10 10 10 x 11.5 x 12.5 x 12.5 x 12.5 x 16 10 10 10 x 16 x 20 x 20 8 8 10 x 11.5 x 11.5 x 12.5 8 8 10 10 10 10 10 10 x 11.5 x 11.5 x 12.5 x 12.5 x 16 x 16 x 20 x 20 10 16 25 35 50 63
Case dimensions d x l (mm)
12.5 x 20 12.5 x 20 12.5 x 25 16 16 x 20 x 20
12.5 x 40 16 x 25 18 x 20 16 18 x 31.5 x 25
820 1000
10 10
x 16 x 16 10 x 20
10
x 20
12.5 x 20 12.5 x 25
16
x 20
12.5 x 20
12.5 x 40 16 x 25 18 x 20 16 18 16 18 x 31.5 x 25 x 31.5 x 31.5 18 18 18 x 31.5 x 35 x 40
1200 1500 1800
10 10 10
x 20 x 20 x 20
10
x 20
12.5 x 20 12.5 x 25 16 x 20
16
x 20
12.5 x 20 12.5 x 25
12.5 x 40 16 x 25 18 x 20 16 18 16 18 18 x 31.5 x 25 x 31.5 x 31.5 x 35
2200 2700 3300 3900
12.5 x 20 12.5 x 25 12.5 x 25 16 x 20
12.5 x 25 16 x 20
18
x 20
18 18
x 35 x 40
12.5 x 40 16 x 25 16 18 x 31.5 x 25 x 31.5
12.5 x 40 16 x 25 18 x 20
18
Please read Cautions and warnings and Important notes at the end of this document.
Page 5 of 32
B41888 Extended useful life 105 C
VR (V DC) CR (F) 4700 5600
10
16
25
35
50
63
Case dimensions d x l (mm) 16 x 25 16 18 18 x 31.5 x 25 x 31.5 18 18 x 35 x 40 18 x 40
12.5 x 40 16 x 25 18 x 20 16 18 18 18 x 31.5 x 25 x 31.5 x 35
6800 8200 10000
18 18
x 35 x 40
Other voltage and capacitance ratings are available upon request.
Please read Cautions and warnings and Important notes at the end of this document.
Page 6 of 32
B41888 Extended useful life 105 C
Technical data and ordering codes CR 120 Hz 20 C F Case ESRmax ESRmax dimensions 10 kHz 120 Hz dxl 40 C 20 C mm 1.630 0.928 0.930 0.512 0.516 0.403 0.400 0.400 0.328 0.240 0.237 0.233 0.190 0.149 0.190 0.226 0.154 0.188 0.143 0.120 0.484 0.406 0.334 0.277 0.227 0.189 0.152 0.126 0.115 0.094 0.084 0.071 0.065 0.059 0.059 0.059 0.052 0.052 0.049 0.045 ESRmax 10 kHz 20 C 0.204 0.116 0.116 0.064 0.064 0.050 0.050 0.050 0.041 0.030 0.030 0.029 0.024 0.019 0.024 0.028 0.019 0.023 0.018 0.015 Zmax 100 kHz 20 C 0.183 0.101 0.101 0.059 0.059 0.046 0.046 0.046 0.039 0.027 0.027 0.026 0.022 0.017 0.022 0.025 0.017 0.021 0.016 0.014 IAC,R 100 kHz 105 C mA 690 900 900 1240 1240 1500 1500 1500 2000 2459 2459 2530 2930 3350 2930 3000 3600 3396 4247 4300 IAC,max Ordering code 100 kHz (composition see 85 C below) mA 966 1260 1260 1736 1736 2100 2100 2100 2800 3443 3442 3542 4102 4690 4102 4200 5040 4755 5946 6020 B41888C3477M*** B41888C3567M*** B41888C3687M*** B41888C3827M*** B41888C3108M*** B41888C3128M*** B41888C3158M*** B41888C3188M*** B41888D3228M*** B41888C3278M*** B41888C3338M*** B41888C3398M*** B41888C3478M*** B41888C3568M*** B41888D3568M*** B41888E3568M*** B41888C3688M*** B41888D3688M*** B41888C3828M*** B41888C3109M***
VR = 10 V DC 470 8 x 11.5 560 10 x 12.5 680 10 x 12.5 820 10 x 16 1000 10 x 16 1200 10 x 20 1500 10 x 20 1800 10 x 20 2200 12.5 x 20 2700 12.5 x 25 3300 12.5 x 25 3900 16 x 20 4700 16 x 25 5600 12.5 x 40 5600 16 x 25 5600 18 x 20 6800 16 x 31.5 6800 18 x 25 8200 18 x 31.5 10000 18 x 35
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d x l = 10 x 20 mm to 18 x 40 mm, excluding 12.5 x 40 mm) 002 = for cut leads, bulk (for 10 mm, excluding 12.5 x 40 mm) 003 = for crimped leads, blister (from d x l = 16 x 20 mm to 18 x 40 mm) 004 = for J leads, blister (from d x l = 10 x 12.5 mm to 18 x 35 mm, excluding 12.5 x 40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d x l = 8 x 11.5 mm to 12.5 x 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d x l = 16 x 20 mm to 18 x 31.5 mm) 012 = for bent 90 leads, blister (for 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 7 of 32
B41888 Extended useful life 105 C
Technical data and ordering codes CR 120 Hz 20 C F Case ESRmax ESRmax dimensions 10 kHz 120 Hz dxl 40 C 20 C mm 1.630 1.632 0.930 0.512 0.516 0.403 0.400 0.328 0.240 0.237 0.233 0.149 0.190 0.226 0.154 0.188 0.143 0.120 0.100 0.612 0.518 0.430 0.361 0.297 0.202 0.168 0.135 0.112 0.103 0.084 0.065 0.065 0.065 0.059 0.059 0.054 0.043 0.040 ESRmax 10 kHz 20 C 0.204 0.204 0.116 0.064 0.064 0.050 0.050 0.041 0.030 0.030 0.029 0.019 0.024 0.028 0.019 0.023 0.018 0.015 0.013 Zmax 100 kHz 20 C 0.183 0.183 0.101 0.059 0.059 0.046 0.046 0.039 0.027 0.027 0.026 0.017 0.022 0.025 0.017 0.021 0.016 0.014 0.012 IAC,R 100 kHz 105 C mA 690 690 900 1240 1240 1500 1500 2000 2459 2459 2530 3350 2930 3000 3600 3200 4247 4300 5327 IAC,max Ordering code 100 kHz (composition see 85 C below) mA 966 966 1260 1736 1736 2100 2100 2800 3443 3442 3542 4690 4102 4200 5040 4480 5946 6020 7457 B41888C4337M*** B41888C4397M*** B41888C4477M*** B41888C4567M*** B41888C4687M*** B41888C4108M*** B41888C4128M*** B41888D4158M*** B41888C4188M*** B41888C4228M*** B41888C4278M*** B41888C4398M*** B41888D4398M*** B41888E4398M*** B41888C4478M*** B41888D4478M*** B41888C4568M*** B41888C4828M*** B41888C4109M***
VR = 16 V DC 330 8 x 11.5 390 8 x 11.5 470 10 x 12.5 560 10 x 16 680 10 x 16 1000 10 x 20 1200 10 x 20 1500 12.5 x 20 1800 12.5 x 25 2200 12.5 x 25 2700 16 x 20 3900 12.5 x 40 3900 16 x 25 3900 18 x 20 4700 16 x 31.5 4700 18 x 25 5600 18 x 31.5 8200 18 x 35 10000 18 x 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d x l = 10 x 20 mm to 18 x 40 mm, excluding 12.5 x 40 mm) 002 = for cut leads, bulk (for 10 mm, excluding 12.5 x 40 mm) 003 = for crimped leads, blister (from d x l = 16 x 20 mm to 18 x 40 mm) 004 = for J leads, blister (from d x l = 10 x 12.5 mm to 18 x 35 mm, excluding 12.5 x 40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d x l = 8 x 11.5 mm to 12.5 x 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d x l = 16 x 20 mm to 18 x 31.5 mm) 012 = for bent 90 leads, blister (for 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 8 of 32
B41888 Extended useful life 105 C
Technical data and ordering codes CR 120 Hz 20 C F Case ESRmax ESRmax dimensions 10 kHz 120 Hz dxl 40 C 20 C mm 1.630 1.632 0.930 0.928 0.516 0.512 0.403 0.400 0.328 0.328 0.237 0.233 0.226 0.149 0.190 0.154 0.188 0.143 0.120 0.100 0.804 0.655 0.536 0.453 0.376 0.316 0.260 0.216 0.177 0.147 0.118 0.098 0.090 0.075 0.075 0.069 0.069 0.058 0.054 0.050 ESRmax 10 kHz 20 C 0.204 0.204 0.116 0.116 0.064 0.064 0.050 0.050 0.041 0.041 0.030 0.029 0.028 0.019 0.024 0.019 0.023 0.018 0.015 0.013 Zmax 100 kHz 20 C 0.183 0.183 0.101 0.101 0.059 0.059 0.046 0.046 0.039 0.039 0.027 0.026 0.025 0.017 0.022 0.017 0.021 0.016 0.014 0.012 IAC,R 100 kHz 105 C mA 690 690 900 900 1240 1240 1500 1500 2000 2000 2459 2530 3000 3350 2930 3600 3200 4247 4300 5327 IAC,max Ordering code 100 kHz (composition see 85 C below) mA 966 966 1260 1260 1736 1736 2100 2100 2800 2800 3442 3542 4200 4690 4102 5040 4480 5946 6020 7457 B41888C5227M*** B41888C5277M*** B41888C5337M*** B41888C5397M*** B41888C5477M*** B41888C5567M*** B41888C5687M*** B41888C5827M*** B41888D5108M*** B41888C5128M*** B41888C5158M*** B41888C5188M*** B41888C5228M*** B41888C5278M*** B41888D5278M*** B41888C5338M*** B41888D5338M*** B41888C5398M*** B41888C5478M*** B41888C5568M***
VR = 25 V DC 220 8 x 11.5 270 8 x 11.5 330 10 x 12.5 390 10 x 12.5 470 10 x 16 560 10 x 16 680 10 x 20 820 10 x 20 1000 12.5 x 20 1200 12.5 x 20 1500 12.5 x 25 1800 16 x 20 2200 18 x 20 2700 12.5 x 40 2700 16 x 25 3300 16 x 31.5 3300 18 x 25 3900 18 x 31.5 4700 18 x 35 5600 18 x 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d x l = 10 x 20 mm to 18 x 40 mm, excluding 12.5 x 40 mm) 002 = for cut leads, bulk (for 10 mm, excluding 12.5 x 40 mm) 003 = for crimped leads, blister (from d x l = 16 x 20 mm to 18 x 40 mm) 004 = for J leads, blister (from d x l = 10 x 12.5 mm to 18 x 35 mm, excluding 12.5 x 40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d x l = 8 x 11.5 mm to 12.5 x 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d x l = 16 x 20 mm to 18 x 31.5 mm) 012 = for bent 90 leads, blister (for 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 9 of 32
B41888 Extended useful life 105 C
Technical data and ordering codes CR 120 Hz 20 C F Case ESRmax ESRmax dimensions 10 kHz 120 Hz dxl 40 C 20 C mm 1.630 0.928 0.930 0.928 0.516 0.403 0.400 0.400 0.328 0.237 0.233 0.149 0.190 0.226 0.154 0.188 0.152 0.144 0.120 0.104 1.011 0.842 0.689 0.561 0.459 0.323 0.271 0.223 0.185 0.152 0.126 0.084 0.084 0.084 0.080 0.080 0.065 0.061 0.052 0.048 ESRmax 10 kHz 20 C 0.204 0.116 0.116 0.116 0.064 0.050 0.050 0.050 0.041 0.030 0.029 0.019 0.024 0.028 0.019 0.023 0.019 0.018 0.015 0.013 Zmax 100 kHz 20 C 0.183 0.101 0.101 0.101 0.059 0.046 0.046 0.046 0.039 0.027 0.026 0.017 0.022 0.025 0.017 0.021 0.017 0.016 0.014 0.012 IAC,R 100 kHz 105 C mA 690 900 900 900 1240 1500 1500 1500 2000 2459 2530 3350 2930 3000 3600 3200 3600 4247 4300 5327 IAC,max Ordering code 100 kHz (composition see 85 C below) mA 966 1260 1260 1260 1736 2100 2100 2100 2800 3442 3542 4690 4102 4200 5040 4480 5040 5946 6020 7458 B41888C7157M*** B41888C7187M*** B41888C7227M*** B41888C7277M*** B41888C7337M*** B41888C7477M*** B41888C7567M*** B41888D7687M*** B41888C7827M*** B41888C7108M*** B41888C7128M*** B41888C7188M*** B41888D7188M*** B41888E7188M*** B41888C7228M*** B41888D7228M*** B41888D7278M*** B41888D7338M*** B41888D7398M*** B41888C7478M***
VR = 35 V DC 150 8 x 11.5 180 10 x 12.5 220 10 x 12.5 270 10 x 12.5 330 10 x 16 470 10 x 20 560 10 x 20 680 10 x 20 820 12.5 x 20 1000 12.5 x 25 1200 16 x 20 1800 12.5 x 40 1800 16 x 25 1800 18 x 20 2200 16 x 31.5 2200 18 x 25 2700 16 x 31.5 3300 18 x 31.5 3900 18 x 35 4700 18 x 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d x l = 10 x 20 mm to 18 x 40 mm, excluding 12.5 x 40 mm) 002 = for cut leads, bulk (for 10 mm, excluding 12.5 x 40 mm) 003 = for crimped leads, blister (from d x l = 16 x 20 mm to 18 x 40 mm) 004 = for J leads, blister (from d x l = 10 x 12.5 mm to 18 x 35 mm, excluding 12.5 x 40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d x l = 8 x 11.5 mm to 12.5 x 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d x l = 16 x 20 mm to 18 x 31.5 mm) 012 = for bent 90 leads, blister (for 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 10 of 32
B41888 Extended useful life 105 C
Technical data and ordering codes CR 120 Hz 20 C F Case ESRmax ESRmax dimensions 10 kHz 120 Hz dxl 40 C 20 C mm 4.920 4.920 1.824 1.030 0.672 0.672 0.518 0.344 0.344 0.410 0.216 0.283 0.312 0.221 0.275 0.224 0.204 0.177 0.159 1.263 1.053 0.842 0.574 0.468 0.383 0.269 0.226 0.186 0.154 0.126 0.126 0.126 0.105 0.105 0.084 0.070 0.069 0.056 ESRmax 10 kHz 20 C 0.615 0.615 0.228 0.129 0.084 0.084 0.065 0.043 0.043 0.051 0.027 0.035 0.039 0.028 0.034 0.028 0.025 0.022 0.020 Zmax 100 kHz 20 C 0.540 0.540 0.203 0.115 0.075 0.075 0.060 0.040 0.040 0.046 0.025 0.032 0.036 0.025 0.031 0.025 0.023 0.020 0.018 IAC,R 100 kHz 105 C mA 500 500 600 1050 1180 1180 1800 2024 2024 1957 2920 2700 2541 3010 2795 3010 3542 3800 4000 IAC,max Ordering code 100 kHz (composition see 85 C below) mA 700 700 840 1470 1652 1652 2520 2834 2834 2740 4088 3780 3557 4214 3914 4214 4959 5320 5600 B41888C6107M*** B41888C6127M*** B41888D6157M*** B41888C6227M*** B41888C6277M*** B41888C6337M*** B41888C6477M*** B41888C6567M*** B41888C6687M*** B41888C6827M*** B41888C6108M*** B41888D6108M*** B41888G6108M*** B41888C6128M*** B41888D6128M*** B41888C6158M*** B41888C6188M*** B41888C6228M*** B41888C6278M***
VR = 50 V DC 100 8 x 11.5 120 8 x 11.5 150 10 x 12.5 220 10 x 16 270 10 x 20 330 10 x 20 470 12.5 x 20 560 12.5 x 25 680 12.5 x 25 820 16 x 20 1000 12.5 x 40 1000 16 x 25 1000 18 x 20 1200 16 x 31.5 1200 18 x 25 1500 16 x 31.5 1800 18 x 31.5 2200 18 x 35 2700 18 x 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d x l = 10 x 20 mm to 18 x 40 mm, excluding 12.5 x 40 mm) 002 = for cut leads, bulk (for 10 mm, excluding 12.5 x 40 mm) 003 = for crimped leads, blister (from d x l = 16 x 20 mm to 18 x 40 mm) 004 = for J leads, blister (from d x l = 10 x 12.5 mm to 18 x 35 mm, excluding 12.5 x 40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d x l = 8 x 11.5 mm to 12.5 x 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d x l = 16 x 20 mm to 18 x 31.5 mm) 012 = for bent 90 leads, blister (for 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 11 of 32
B41888 Extended useful life 105 C
Technical data and ordering codes CR 120 Hz 20 C F Case ESRmax ESRmax dimensions 10 kHz 120 Hz dxl 40 C 20 C mm 5.413 4.328 5.766 4.616 3.075 2.464 1.986 1.592 1.688 1.688 1.236 1.037 0.832 0.717 0.772 0.960 0.541 0.761 0.518 0.441 0.375 2.030 1.672 1.386 1.137 0.947 0.758 0.632 0.517 0.421 0.344 0.291 0.242 0.203 0.167 0.167 0.167 0.139 0.139 0.095 0.076 0.063 ESRmax 10 kHz 20 C 0.541 0.541 0.577 0.577 0.308 0.308 0.199 0.199 0.169 0.169 0.124 0.104 0.104 0.072 0.077 0.096 0.054 0.076 0.052 0.044 0.038 Zmax 100 kHz 20 C 0.488 0.488 0.500 0.500 0.279 0.279 0.180 0.180 0.153 0.153 0.112 0.094 0.094 0.065 0.070 0.087 0.049 0.069 0.047 0.040 0.034 IAC,R 100 kHz 105 C mA 283 283 323 323 474 474 644 644 800 800 1020 1161 1161 1629 1460 1302 1910 1584 2094 2366 2708 IAC,max Ordering code 100 kHz (composition see 85 C below) mA 396 396 453 452 664 664 901 902 1120 1120 1428 1625 1625 2281 2045 1823 2674 2217 2932 3313 3792 B41888C8566M*** B41888C8686M*** B41888C8826M*** B41888C8107M*** B41888C8127M*** B41888C8157M*** B41888C8187M*** B41888C8227M*** B41888C8277M*** B41888C8337M*** B41888C8397M*** B41888C8477M*** B41888C8567M*** B41888C8687M*** B41888D8687M*** B41888E8687M*** B41888C8827M*** B41888D8827M*** B41888C8128M*** B41888C8158M*** B41888C8188M***
VR = 63 V DC 56 8 x 11.5 68 8 x 11.5 82 10 x 12.5 100 10 x 12.5 120 10 x 16 150 10 x 16 180 10 x 20 220 10 x 20 270 12.5 x 20 330 12.5 x 20 390 12.5 x 25 470 16 x 20 560 16 x 20 680 12.5 x 40 680 16 x 25 680 18 x 20 820 16 x 31.5 820 18 x 25 1200 18 x 31.5 1500 18 x 35 1800 18 x 40
Composition of ordering code *** = Version 000 = for standard leads, bulk 001 = for kinked leads, bulk (from d x l = 10 x 20 mm to 18 x 40 mm, excluding 12.5 x 40 mm) 002 = for cut leads, bulk (for 10 mm, excluding 12.5 x 40 mm) 003 = for crimped leads, blister (from d x l = 16 x 20 mm to 18 x 40 mm) 004 = for J leads, blister (from d x l = 10 x 12.5 mm to 18 x 35 mm, excluding 12.5 x 40 mm) 008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d x l = 8 x 11.5 mm to 12.5 x 25 mm) 009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d x l = 16 x 20 mm to 18 x 31.5 mm) 012 = for bent 90 leads, blister (for 16 and 18 mm)
Please read Cautions and warnings and Important notes at the end of this document.
Page 12 of 32
B41888 Extended useful life 105 C
Useful life depending on ambient temperature TA under ripple current operating conditions1) d = 8 mm
d = 10 mm
1) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life graphs.
Please read Cautions and warnings and Important notes at the end of this document.
Page 13 of 32
B41888 Extended useful life 105 C
Useful life depending on ambient temperature TA under ripple current operating conditions2) d = 12.5 mm
Frequency factor of permissible ripple current IAC versus frequency f
2) Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life graphs.
Please read Cautions and warnings and Important notes at the end of this document.
Page 14 of 32
B41888 Extended useful life 105 C
Taping, packing and lead configurations Taping Single-ended capacitors are available taped in Ammo pack from diameter 5 to 18 mm as follows: Lead spacing F = 2.5 mm ( d = 5 ... 6.3 mm) Lead spacing F = 3.5 mm ( d = 8 mm) Lead spacing F = 5.0 mm (from d x l = 10 x 12.5 mm to 12.5 x 30 mm) Lead spacing F = 7.5 mm ( d = 16 ... 18 mm). Lead spacing 2.5 mm ( d = 5 ... 6.3 mm) Last 3 digits of ordering code: 007
Dimensions in mm d 5 F H W W0 W1 W2 H0 P P0 P1 I1 t h D0
2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0 6.3 Toler- +0.8 0.75 0.5 min. 0.5 max. 0.5 1.0 0.2 0.5 max. 0.2 max. 0.2 ance 0.2
Please read Cautions and warnings and Important notes at the end of this document.
Page 15 of 32
B41888 Extended useful life 105 C
Lead spacing 3.5 mm ( d = 8 mm) Last 3 digits of ordering code: 006
Dimensions in mm d F H 8 3.5 18.5 Toler- +0.8 1.0 ance 0.2 W 18.0 0.5 W0 12.5 min. W1 9.0 0.5 W2 1.5 P 12.7 P0 12.7 0.2 P1 4.6 0.5 I1 1.0 t 0.7 h 1.0 D0 4.0
max. 1.0
max. 0.2
max. 0.2
Please read Cautions and warnings and Important notes at the end of this document.
Page 16 of 32
B41888 Extended useful life 105 C
Lead spacing 5.0 mm ( d = 5 ... 8 mm) Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (from d x l = 10 x 12.5 mm to 12.5 x 30 mm) Last 3 digits of ordering code: 008
Dimensions in mm d 5 6.3 8 10 5.0 F 5.0 H 18.5 20.0 19.0 18.0 12.5 9.0 1.5 W W0 W1 9.0 W2 1.5 H0 16.0 16.0 P 12.7 12.7 12.7 15.0 1.0 P0 12.7 12.7 12.7 15.0 0.2 P1 3.85 3.85 3.85 5.0 0.5 max. 0.2 max. 0.2 1.0 0.7 1.0 4.0 I1 1.0 t 0.7 h 1.0 D0 4.0
18.0 5.5
12.5 19.0 Toler- +0.8 0.75 0.5 min. 0.5 max. 0.5 ance 0.2
Please read Cautions and warnings and Important notes at the end of this document.
Page 17 of 32
B41888 Extended useful life 105 C
Lead spacing 7.5 mm ( d = 16 ...18 mm) Last 3 digits of ordering code: 009
Dimensions in mm d 16 F H W W0 12.5 min. W1 9.0 0.5 W2 1.5 P 30.0 P0 15.0 0.2 P1 3.75 0.5 I1 1.0 t 0.7 P 0 h 0 D0 4.0
7.5 18.5 18.0 18 *) Toler0.5 0.8 0.5 ance +0.75
max. 1.0
max. 0.2 1.0 1.0 0.2
*) Available only for case dimensions 18 x 20, 18 x 25 and 18 x 31.5 mm
Please read Cautions and warnings and Important notes at the end of this document.
Page 18 of 32
B41888 Extended useful life 105 C
Packing units and box dimensions Ammo pack Case size dxl mm 5 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 16 10 x 20 12.5 x 20 12.5 x 25 16 x 20 16 x 25 16 x 31.5 18 x 20 18 x 25 18 x 31.5 Dimensions (mm) Amax 345 345 345 345 345 345 345 345 315 315 315 315 315 315 Bmax 55 55 55 55 60 60 65 65 65 65 65 65 65 65 Cmax 240 290 240 280 200 200 280 280 275 275 275 275 275 275 Packing units pcs. 2000 2000 1000 750 500 500 500 500 300 300 300 250 250 250
Please read Cautions and warnings and Important notes at the end of this document.
Page 19 of 32
B41888 Extended useful life 105 C
Kinked or cut leads Single-ended capacitors are available with kinked or cut leads. Other lead configurations also available upon request. Kinked leads Last 3 digits of ordering code: 001 With stand-off rubber seal Case size d x l (mm) 10 x 20 12.5 x 20 12.5 x 25 16 x 20 16 x 25 16 x 31.5 18 x 20 18 x 25 18 x 31.5 18 x 35 18 x 40 With flat rubber seal Dimensions (mm) a 0.5 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
Please read Cautions and warnings and Important notes at the end of this document.
Page 20 of 32
B41888 Extended useful life 105 C
Cut leads Last 3 digits of ordering code: 002 With stand-off rubber seal Case size d x l (mm) 10 x 12.5 10 x 16 10 x 20 12.5 x 20 12.5 x 25 With flat rubber seal 16 x 20 16 x 25 16 x 31.5 18 x 20 18 x 25 18 x 31.5 18 x 35 18 x 40 20 x 20 20 x 25 20 x 30 20 x 35 20 x 40 22 x 30 22 x 35 22 x 40 Dimensions (mm) a 0.5 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0
Please read Cautions and warnings and Important notes at the end of this document.
Page 21 of 32
B41888 Extended useful life 105 C
PAPR leads (Protection Against Polarity Reversal) These lead configurations ensure correct placement of the capacitor on the PCB with regard to polarity. PAPR leads are available for diameters from 10 mm up to 20 mm. There are three configurations available: Crimped leads, J leads, bent 90 leads Crimped leads Last 3 digits of ordering code: 003 With stand-off rubber seal With flat rubber seal
Suggestion for PCB hole diameter
Case size d x l (mm) 16 x 20 16 x 25 16 x 31.5 18 x 20 18 x 25 18 x 31.5 18 x 35 18 x 40 20 x 20 20 x 25 20 x 30 20 x 35 20 x 40
Dimensions (mm) B 0.2 C 0.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
D 0.1 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.3 1.6 1.6 1.6 1.6 1.6
E 0.1 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
a 0.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 10.0 10.0 10.0 10.0 10.0
b 0.8 0.05 0.8 0.05 0.8 0.05 0.8 0.1 0.8 0.1 0.8 0.1 0.8 0.1 0.8 0.1 1.0 0.1 1.0 0.1 1.0 0.1 1.0 0.1 1.0 0.1
Please read Cautions and warnings and Important notes at the end of this document.
Page 22 of 32
B41888 Extended useful life 105 C
J leads Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size d x l (mm) 10 x 12.5 10 x 16 10 x 20 12.5 x 20 12.5 x 25 16 x 20 16 x 25 16 x 31.5 18 x 20 18 x 25 18 x 31.5 18 x 35
Dimensions (mm) C 0.5 E 0.5 3.2 3.2 3.2 3.2 3.2 3.5 3.5 3.5 3.5 3.5 3.5 3.5 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7
J 0.2 1.2 1.2 1.2 1.2 1.2 1.6 1.6 1.6 1.6 1.6 1.6 1.6
a 0.5 5.0 5.0 5.0 5.0 5.0 7.5 7.5 7.5 7.5 7.5 7.5 7.5
b 0.6 0.05 0.6 0.05 0.6 0.05 0.6 0.05 0.6 0.05 0.8 0.05 0.8 0.05 0.8 0.05 0.8 0.1 0.8 0.1 0.8 0.1 0.8 0.1
Please read Cautions and warnings and Important notes at the end of this document.
Page 23 of 32
B41888 Extended useful life 105 C
Bent 90 leads for horizontal mounting pinning Last 3 digits of ordering code: 012
Case size d x l (mm) 16 x 20 16 x 25 16 x 31.5 18 x 20 18 x 25 18 x 31.5 18 x 35 18 x 40
Dimensions (mm) C 0.5 E 0.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0
F 0.5 12.0 12.0 12.0 13.0 13.0 13.0 13.0 13.0
a 0.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
b 0.8 0.05 0.8 0.05 0.8 0.05 0.8 0.1 0.8 0.1 0.8 0.1 0.8 0.1 0.8 0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and Important notes at the end of this document.
Page 24 of 32
B41888 Extended useful life 105 C
Overview of packing units and code numbers for case sizes 5 x 11 ... 16 x 31.5 PAPR Case size dxl mm 5 x 11 6.3 x 11 8 x 11.5 10 x 12.5 10 x 16 10 x 20 12.5 x 20 12.5 x 25 12.5 x 30 12.5 x 35 12.5 x 40 16 x 20 16 x 25 16 x 31.5 The last three digits of the complete ordering code state the lead configuration Standard, bulk pcs. 2000 2500 1000 1000 1000 500 350 250 200 175 175 250 250 200 000 300 300 300 Code 006 007 008 009 F (mm) d (mm) 3.5 2.5 5 7.5 8 5...6.3 5...12.5 16...18 200 200 250 001 200 200 250 002 200 200 344 003 200 200 344 004 120 120 120 012 Taped, Ammo pack pcs. 2000 2000 1000 750 500 500 500 500 500 350 500 1000 1000 500 350 500 675 675 500 300 225
1) 1)
Kinked leads, bulk pcs.
Cut leads, bulk pcs.
Crimped J leads, leads, blister blister pcs. pcs.
Bent 90 leads, blister pcs.
1) Available upon request
Please read Cautions and warnings and Important notes at the end of this document.
Page 25 of 32
B41888 Extended useful life 105 C
Overview of packing units and code numbers for case sizes 18 x 20 ... 25 x 40 PAPR Case size dxl mm 18 x 20 18 x 25 18 x 31.5 18 x 35 18 x 40 20 x 20 20 x 25 20 x 30 20 x 35 20 x 40 22 x 30 22 x 35 22 x 40 25 x 40 The last three digits of the complete ordering code state the lead configuration Standard, bulk pcs. 175 150 100 100 125 125 125 100 100 100 80 80 80 40 000 Code 007 008 009 F (mm) d (mm) 2.5 5 7.5 4...6.3 6.3...12.5 16...18 001 002 003 004 012 Taped, Ammo pack pcs. 250 250 250 Kinked leads, bulk pcs. 175 150 100 100 100 Cut leads, bulk pcs. 175 150 100 100 100 125 125 100 100 100 100 100 100 Crimped J leads, leads, blister blister pcs. pcs. 200 200 150 150 120 200 200 120 120 120 200 200 150 150 Bent 90 leads, blister pcs. 120 120 120 150 72
Please read Cautions and warnings and Important notes at the end of this document.
Page 26 of 32
B41888 Extended useful life 105 C
Cautions and warnings Personal safety The electrolytes used by EPCOS have not only been optimized with a view to the intended application, but also with regard to health and environmental compatibility. They do not contain any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide (DMAC). Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They contain flame-retarding substances which will quickly extinguish any flame that may have been ignited. As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce operating electrolytes. However, in exceptional cases, such materials must be used in order to achieve specific physical and electrical properties because no safe substitute materials are currently known. However, the amount of dangerous materials used in our products has been limited to an absolute minimum. Nevertheless, the following rules should be observed when handling Al electrolytic capacitors: Any escaping electrolyte should not come into contact with eyes or skin. If electrolyte does come into contact with the skin, wash the affected parts immediately with running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If symptoms persist, seek medical treatment. Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be well ventilated. Clothing that has been contaminated by electrolyte must be changed and rinsed in water.
Please read Cautions and warnings and Important notes at the end of this document.
Page 27 of 32
B41888 Extended useful life 105 C
Product safety The table below summarize the safety instructions that must be observed without fail. A detailed description can be found in the relevant sections of chapter "General technical information". Topic Safety information Reference Chapter "General technical information" 1 "Basic construction of aluminum electrolytic capacitors" 3.1.6 "Reverse voltage" 7.2 "Maximum permissible operating temperature" 10 "Maintenance"
Polarity
Make sure that polar capacitors are connected with the right polarity.
Reverse voltage Upper category temperature Maintenance
Voltages polarity classes should be prevented by connecting a diode. Do not exceed the upper category temperatur.
Mounting position of screw terminal capacitors Mounting of single-ended capacitors
Make periodic inspections of the capacitors. Before the inspection, make sure that the power supply is turned off and carefully discharge the electricity of the capacitors. Do not apply any mechanical stress to the capacitor terminals. Do not mount the capacitor with the terminals (safety vent) upside down.
Robustness of terminals
Soldering
11.1 "Mounting positions of capacitors with screw terminals" The internal structure of single-ended capacitors 11.4 might be damaged if excessive force is applied to "Mounting the lead wires. considerations for Avoid any compressive, tensile or flexural stress. single-ended capacitors" Do not move the capacitor after soldering to PC board. Do not pick up the PC board by the soldered capacitor. Do not insert the capacitor on the PC board with a hole space different to the lead space specified. The following maximum tightening torques must 11.3 not be exceeded when connecting screw "Mounting torques" terminals: M5: 2 Nm M6: 2.5 Nm Do not exceed the specified time or temperature 11.5 limits during soldering. "Soldering"
Page 28 of 32
Please read Cautions and warnings and Important notes at the end of this document.
B41888 Extended useful life 105 C
Topic
Safety information
Soldering, cleaning agents Passive flammability Active flammability
Reference Chapter "General technical information" Do not allow halogenated hydrocarbons to come 11.6 into contact with aluminum electrolytic capacitors. "Cleaning agents" Avoid external energy, such as fire or electricity. 8.1 "Passive flammability" Avoid overload of the capacitors. 8.2 "Active flammability" Reference Chapter "Capacitors with screw terminals" "Screw terminals accessories"
Breakdown strength Do not damage the insulating sleeve, especially of insulating when ring clips are used for mounting. sleeves
Please read Cautions and warnings and Important notes at the end of this document.
Page 29 of 32
B41888 Extended useful life 105 C
Symbols and terms Symbol C CR CS CS,T Cf d dmax ESL ESR ESRf ESRT f I IAC IAC,rms IAC,f IAC,max IAC,R IAC,R (B) Ileak Ileak,op l lmax R Rins Rsymm T T TA TC TB t t tb English Capacitance Rated capacitance Series capacitance Series capacitance at temperature T Capacitance at frequency f Case diameter, nominal dimension Maximum case diameter Self-inductance Equivalent series resistance Equivalent series resistance at frequency f Equivalent series resistance at temperature T Frequency Current Alternating current (ripple current) Root-mean-square value of alternating current Ripple current at frequency f Maximum permissible ripple current Rated ripple current Rated ripple current for base cooling Leakage current Operating leakage current Case length, nominal dimension Maximum case length (without terminals and mounting stud) Resistance Insulation resistance Balancing resistance Temperature Temperature difference Ambient temperature Case temperature Capacitor base temperature Time Period Service life (operating hours) German Kapazitat Nennkapazitat Serienkapazitat Serienkapazitat bei Temperatur T Kapazitat bei Frequenz f Gehausedurchmesser, Nennma Maximaler Gehausedurchmesser Eigeninduktivitat Ersatzserienwiderstand Ersatzserienwiderstand bei Frequenz f Ersatzserienwiderstand bei Temperatur T Frequenz Strom Wechselstrom Wechselstrom, Effektivwert Wechselstrom bei Frequenz f Maximal zulassiger Wechselstrom Nennwechselstrom Nennwechselstromstrom fur Bodenkuhlung Ableitstrom Ableitstrom bei Betrieb Gehauselange, Nennma Maximale Gehauselange (ohne Anschlusse und Gewindebolzen) Widerstand Isolationswiderstand Symmetrierwiderstand Temperatur Temperaturdifferenz Umgebungstemperatur Gehausetemperatur Temperatur des Becherbodens Zeit Zeitraum Brauchbarkeitsdauer (Betriebszeit)
Please read Cautions and warnings and Important notes at the end of this document.
Page 30 of 32
B41888 Extended useful life 105 C
Symbol V VF Vop VR VS XC XL Z ZT tan 0 r Notes
English Voltage Forming voltage Operating voltage Rated voltage, DC voltage Surge voltage Capacitive reactance Inductive reactance Impedance Impedance at temperature T Dissipation factor Failure rate Absolute permittivity Relative permittivity Angular velocity; 2 f
German Spannung Formierspannung Betriebsspannung Nennspannung, Gleichspannung Spitzenspannung Kapazitiver Blindwiderstand Induktiver Blindwiderstand Scheinwiderstand Scheinwiderstand bei Temperatur T Verlustfaktor Ausfallrate Elektrische Feldkonstante Dielektrizitatszahl Kreisfrequenz; 2 f
All dimensions are given in mm.
Please read Cautions and warnings and Important notes at the end of this document.
Page 31 of 32
Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
Page 32 of 32


▲Up To Search▲   

 
Price & Availability of B41888C3568M000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X